Permit: T19CM01156

Parcel: 137071430


Addresses:

5247 S 9TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/22/2019 PLUMBING - FINAL Approved add sediment trap at water heater. Secure b venting and add three screws per joint no tape needed. Terminate T&P piping either outside the closure or into a pan so it’s visible if it starts leaking.
02/20/2019 PLUMBING - FINAL Partial Approval water heater unsafe many things incorrect. Plumber is going to replace it, recall inspection after this work has been completed for gas clearance. Inside of house OK.