Permit: T19CM01081

Parcel: 123040430


Addresses:

2806 E LINDEN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/22/2019 FRAMING Approved
03/20/2019 FRAMING Denied 1 Shall seal all top plate penetrations with fire rated foam or caulk.
1080, denied
1- Stucco mesh okay for brown coat.
2- Shall provide shield plates on top and sole plate to protect sanitary waste and vent pipes.
3- Shall provide minimum of 18 inches of stand pipe for clothes washer waste line.
4- Shall provide sanitary tees for the the clothes washer and lavatory trap arms.
5- Shall provide mission specialty couplings when transition of dissimilar material made. Fernco couplings not approved within the structure.
6- Shall provide a water test on dwv system.
03/06/2019 FRAMING Not ready for Inspection Informed builder to schedule with intermediates