Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2019 | FRAMING | Approved | ||
| 03/20/2019 | FRAMING | Denied | 1 Shall seal all top plate penetrations with fire rated foam or caulk. 1080, denied 1- Stucco mesh okay for brown coat. 2- Shall provide shield plates on top and sole plate to protect sanitary waste and vent pipes. 3- Shall provide minimum of 18 inches of stand pipe for clothes washer waste line. 4- Shall provide sanitary tees for the the clothes washer and lavatory trap arms. 5- Shall provide mission specialty couplings when transition of dissimilar material made. Fernco couplings not approved within the structure. 6- Shall provide a water test on dwv system. |
|
| 03/06/2019 | FRAMING | Not ready for Inspection | Informed builder to schedule with intermediates |