Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T19CM00756

Parcel: 141364980

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T19CM00756

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/27/2019 EXT METAL CLIPS/EXT SHEATHING Approved
03/25/2019 EXT METAL CLIPS/EXT SHEATHING Denied 1. South garage door shear missing field nails
2. Missing double row nailing above LSTHD8 hold downs
3. Missing field nailing at top of shear wall at back of garage and renail at overshot locations
4. Missing field nailing at top of shear wall in bedroom #2
5. Shim 3 point bearing trusses on patio
6. Nail off southeast diagonal brace
7. Re-nail roof above garage south plane.