Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T19CM00756
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/27/2019 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
03/25/2019 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1. South garage door shear missing field nails 2. Missing double row nailing above LSTHD8 hold downs 3. Missing field nailing at top of shear wall at back of garage and renail at overshot locations 4. Missing field nailing at top of shear wall in bedroom #2 5. Shim 3 point bearing trusses on patio 6. Nail off southeast diagonal brace 7. Re-nail roof above garage south plane. |