Permit: T19CM00698

Parcel: 140241390


Addresses:

1032 E GANLEY RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/20/2019 PLUMBING - FINAL Approved this approval is only for one flex piece of piping under trailer that was changed to hard piping. Everything else was approved on prior inspections. OK to clear gas for reconnection.
02/12/2019 PLUMBING - FINAL Not ready for Inspection APPROVAL WAS REVERSED DUE TO FLEX PIPING UNDER TRAILER.
02/07/2019 PLUMBING - FINAL Not ready for Inspection water heater has no B venting needs to be 1 foot above roofline. Need sediment trap installed at water heater. Need T and P piping installed. Range and furnace inside OK