Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T19CM00605

Parcel: 115201740


Addresses:

1825 W LESTER ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/10/2019 MECHANICAL - FINAL Approved
05/07/2019 MECHANICAL - FINAL Denied Label sub panel, no exhaust vent for dryer, no access to roof, caulk around toilets, receptacle in master bedroom incorrectly wired refrigerator receptacle incorrectly wired dishwasher hose not installed correctly, no anti-siphon hose bib, missing exterior electrical cover west side of home. Stopped inspection