Permit: T19CM00140

Parcel: 130121010


Addresses:

3758 E ELLINGTON PL

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
01/17/2019 PLUMBING - ROUGH, SOIL Approved
01/15/2019 PLUMBING - ROUGH, SOIL Correction Required Green tracer wire req at all yard area sewer lines including inder patio cover on dirt.
5’ head of water req for all drainage and interior pipe water test.
Test also includes no hub area at ABS to Clay sewer pipe.
N-bath wet vent. Too many fixtures on vertical wet vent. No side inlet allowed on water closet. Sudsing appliance not correct distance other fixtures.
Repair all and recall this inspection.