Permit: T19CM00007

Parcel: 137100820


Addresses:

5425 S ALASKA DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/11/2019 EXT METAL CLIPS/EXT SHEATHING Approved
04/09/2019 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection comply with previous
Complete nailing to siding and roof sheating
missing anchor bolts throughout stopped inspection
04/02/2019 EXT METAL CLIPS/EXT SHEATHING Correction Required ADDITIONAL ANCHOR BOLTS ARE REQUIRED ON BOTTOM PLATE
ADDITIONAL NAILING IS REQURIED ON SIDING (8" OC EDGES 12" OC FIELD)
ROOF SHEATHING MUST BE PLACED PERPENDICULAR TO FRAMING MEMBERS AND END JOINTS MUST BE STAGGERED. PLEASE RE-CALL FOR ON SITE INSPECTION.
04/02/2019 EXT METAL CLIPS/EXT SHEATHING Denied Secure t 1-11 6" " of all edges and 12" in field