Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan: T19BA00019

Parcel: 12008644A


Addresses:

222 W IRVINGTON RD

Inspection Status: Basin - Good

Inspection History: COT - BASN - Drainage/Basin - Annual Inspection - Recur

Date Description Inspector Results Comments
04/19/2022 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good GOOD
05/18/2021 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
06/16/2020 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
02/15/2023 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
07/15/2019 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
03/07/2024 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good
03/06/2025 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Fair It looks as if the geotex fabric was stretched across drywell inlet openings before covers were installed. This condition is making a very effective debris catcher, clogging the openings. Riprap should be used around the openings instead and the geotex cleared out...
03/27/2023 COT - BASN - Drainage/Basin - Annual Inspection - Recur Basin - Good