Inspection History Details
Inspection Status: Approved
Inspection History: CERTIFICATE OF OCCUPANCY
Permit Number - T18OT01232
Inspection Description - CERTIFICATE OF OCCUPANCY
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2019 | CERTIFICATE OF OCCUPANCY | Approved | make sure to install a sign on backdoor saying door is to remain unlocked during business hours”, due to door still having a deadbolt | |
02/27/2019 | CERTIFICATE OF OCCUPANCY | Partial Approval | back door of restaurant still needs to be made accessible with a door that opens out including panic bar hardware. It’s also recommended that the piping on south side of the building is secured to the exterior wall. | |
01/31/2019 | CERTIFICATE OF OCCUPANCY | Not ready for Inspection | no access to inside, no message left. Just on outside of building I can tell several previous corrections still need to be addressed. Storm security door is not an accessible door hardware for an exit. Water heater needs an approved enclosure the current one is not an approved one. Accessible parking space lines need to be blue and painted. | |
12/12/2018 | CERTIFICATE OF OCCUPANCY | Denied | Provide accessibility parking and signs provide emergency lighting at exit doors Provide accessible door hardware at rear exit door exterior water heater not to code provide enclosure seal openings in sub panels AC circuit conduit to be rigid added potable water PVC to be approved material and insulated |