Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18OT01028

Parcel: 119413710


Addresses:

3820 S PANDORA AV


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T18OT01028

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
11/08/2018 COT - ENGR - Signage Final hthrall Approved Entered by HTHRALL1 - Revised plans were submitted to show one caisson footer and pole with cover rather than solid concrete base, and height adjusted.
10/18/2018 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - David Roberts, Site Inspection Supervisor, inspected 10/18/18. Sign placement was marked on site. Reviewed photos. Slope down to sign base. Sign 7.33' wide and 9' tall from base. Sign height measured from average of grade within 5' of sign base would allow for sign increase in height of 9" without any issue. Drainage area would be partially blocked with heavy water flow fairly quickly with the proposed masonry base. Drainage is the issue. Structural engineering (building code division) advised engineered plans and calcs needed for sign structure surface over 60 square feet - which this sign is. However, Engineering (floodplain division) would require water drainage holes through masonry base for water flow to the detention basin. Staff suggestion for resolution - sign installation on a double or single caisson footer with pole cover(s) - without masonry base - does not need structural engineered plans at 45.21 sq.ft. sign area/ structural surface area, and with clearance under cabinet unobstructed, would allow sufficient water flow to the detention basin. Called contractor immediately to discuss. Contractor agreed to revise drawing to remove masonry base, have single caisson footer at enlarged footer dimension of 2' wide by 5' deep, and provide a pole cover for support pole (per code). The sign then does not need engineered plans and will be noted at 9'9" on the plan from average grade. Revised drawings will be sent. (Heather talked with Bill Fields, owner of Territorial Signs.)
10/12/2018 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - Continued review of documents received for sign placement. Discuss with inspector for setback/location and grade check (height) under new code versus old code original project submitted under. On plans: Outdoor Lighting Code addressed Electric notes addressed Sign area addressed for monument/premise
10/05/2018 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - Received email with copy of recordation sheets of utility easement abandonments/releases and utility release from SW Gas for monument sign placement.
10/02/2018 COT - ENGR - Signage Final hthrall1 Continued Entered by HTHRALL1 - Confirming utility easements abandoned or release letters for sign placement. Contacted WLB engineering for assistance with obtaining copies of their recordation sheets.
09/28/2018 COT - ENGR - Signage Final Hthrall Partial Approval Entered by HTHRALL1 - RE: proposed monument (digital message center) For: Dynamite Car Wash AT: 3820 S Pandora Av Permit: T18OT01028 Reviewer: H. Thrall Date: 9/27/18 STATUS: SIGN MEETS SIGN STANDARDS, PARTIAL APPROVAL ISSUED FOR FOLLOWING ITEMS TO BE PROVIDED FOR PERMIT RECORD, AND SPECIFIC NOTES NEEDED ON SHEET 1 1) Acknowledged from email dated 3/12/18 all easements along Ajo were abandoned and recordation occured by WBL Group. For permit record, as the easements were shown on the development plan from 2015, please provide copies of recordation of abandonment. 2) Obtain separate electrical permit for routing power to the sign and advise of permit number. 3) Provide notes on Sheet 1 that the "DIGITAL MESSAGE CENTER IS A MASTER/MIRROR SYSTEM AND WILL DISPLAY SYNCHRONIZED MESSAGE AND CHANGES ON BOTH SIDES". 4) ON SHEET 1, PROVIDE NOTE THAT STATE" SIGN MESSAGE MAY CHANGE A MAXIMUM OF 1 TIME PER MINUTE, BOTH FACED SYNCHRONIZED - NO ANIMATION" PER 7A.6.4.C OF THE UNIFIED DEVELOPMENT CODE (UDC). 5) CALL OUT THE LOCATION OF THE LIGHT SENSORS ON THE SIGN CABINET TO BE USED FOR METHOD OF DIMMING TO 200 UNITS (AS NOTED ON PLAN FROM SUNSET TO SUNRISE). 6) APPEARS TWO CABINETS - CALL OUT CONNECTIONS OR CLARIFY IF ONE MASTER CABINET RETAINER WITH SEPARATE COMPARTMENTS (I.E NON-ILLUMINATED MESSAGE AREA ABOVE DIGITAL CENTER) 7) BLUE STAKE AREA AND MARK PROPERTY LINES FOR INSPECTIONS, ADVISE WHEN COMPLETED. 8) EMAIL UPDATED SHEET 1 AND RECORDATIONS OF ABANDONED EASEMENTS TO HEATHER.THRALL@TUCSONAZ.GOV