Permit: T18OT00867

Parcel: 141220280


Addresses:

9255 S RITA RD


Inspection Status: Approved

Inspection History: SIGN SITE REVIEW

Permit Number - T18OT00867

Inspection Description - SIGN SITE REVIEW

Inspection Status - Approved

Date Description Inspector Results Comments
10/08/2018 SIGN SITE REVIEW Approved NO APPEAL TO DIRECTOR'S NOTICE OF DECISION FOR SINGULAR SIGN DESIGN OPTION. TOTAL $508.55

ENGINEERING APPROVED.

OK TO RELEASE PERMIT 10/9/18.

FOOTER INSTALLED INSIDE TRUCK SCALE'S BASE - PROVIDE NOTARIZED LETTER FROM CONTRACTOR INDICATING FOOTER INSTALLED PER ENGINEERED PLANS.
08/27/2018 SIGN SITE REVIEW Continued Reviewed resubmittal received by email.

Needs 4 examinations for SDRC:
increased height of pole sign
no pole covers
increased sign area for pole sign (110 square feet) 100 sqft main cabinet and 10 sq ft side arm cabinet
bottom cabinet is double faced and perpendicular to 100 sqft main cabinet = multi sided sign
08/16/2018 SIGN SITE REVIEW Correction Required RE: PROPOSED FREESTANDING SIGN
FOR: CAT SCALES
AT: 9255 S RITA RD / PILOT TRUCK STOP
PERMIT: T18OT00867
REVIEWER: H.THRALL
DATE: 8/15/18

1) ACKNOWLEDGED THE PROPOSAL IS A REQUEST FOR A REVIEW FOR A SIGN DESIGN OPTION. SPECIFIC ASPECTS THAT NEED TO BE ADDRESSED VIA THE SIGN DESIGN OPTION (SDO) PROCESS WILL BE NOTED WITH **ASTERISKS** BELOW, AFTER GENERAL PLAN CORRECTIONS.


THE FOLLOWING COMMENTS ARE PLAN CORRECTIONS:

2) OUTDOOR LIGHTING CODE:
a) OLC 501.3 - NOTE MAXIMUM COLOR TEMPERATURE OF INTERIOR ILLUMINATED SIGN IS 4400K. BOTH CABINETS

3) ELECTRICAL
a) NEC 600 - ID WHERE POWER IS PROVIDED TO THE SIGN
b) NEC 600 - ID SHUT OFF SWITCH - FOR BOTH CABINETS? OR DOES EACH HAVE IT'S OWN? SHOW.
c) ASSUME SMALLER CABINET IS LIT. PROVIDE VOLTS, AMPS, CIRCUITS, LIGHTING TYPE - OR CLARIFY IF NOT LIT.

4) STRUCTURAL - ENGINEERING ACKNOWLEDGED, BUT WILL NOT BE REVIEWED FURTHER UNTIL AFTER SDRC PROCESS, OTHERWISE REVIEW FEES APPLY.
SHOULD THE PROPOSAL BE APPROVED BY SDRC, PROVIDE:
a) NOTE CONNECTION TO CABINET FROM POLES
b) SHOW SMALLER CABINET CONNECTION

SIGN STANDARDS: UDC 7A 10.2.
a) **SIGN HEIGHT EXCEEDS A POLE SIGN**
b) **SIGN AREA EXCEEDS A POLE SIGN**
c) **NO POLE COVERS SHOWN FOR THIS SIGN**
d) **SIGN HAS TWO CABINETS, ONE PERPENDICULAR TO THE OTHER, WITH MULTIPLE (MORE THAN TWO) FACES.**

REVISE: SIGN AREA SHOULD INCLUDE THE SMALLER PERPENDICULAR CABINET ON BOTH THE APPLICATION AND THE DRAWING, ALONG WITH THE LARGER CABINET.

SPECIFY DISTANCE FROM SOUTH PROPERTY LINE TO SIGN FOR SDRC REVIEW. (VISIBILITY FROM FREEWAY)

HEIGHT - IS TAKEN BY AVERAGING THE POINTS 5' AWAY FROM THE SIGN IN 4 CARDINAL DIRECTIONS - FRONT CENTER OF SIGN AND ENDS OF SIGN. HEIGHT ON PLANS IS NOTED FROM "TOP OF CURB"...?

FURTHER REVIEW COMMENTS MAY BE FORTHCOMING. OFFICIAL REFERRAL TO SDRC FORTHCOMING, WITH APPLICATIONS FOR A SINGULAR SIGN DESIGN OPTION.