Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: SIGN SITE REVIEW
Permit Number - T18OT00867
Inspection Description - SIGN SITE REVIEW
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/08/2018 | SIGN SITE REVIEW | Approved | NO APPEAL TO DIRECTOR'S NOTICE OF DECISION FOR SINGULAR SIGN DESIGN OPTION. TOTAL $508.55 ENGINEERING APPROVED. OK TO RELEASE PERMIT 10/9/18. FOOTER INSTALLED INSIDE TRUCK SCALE'S BASE - PROVIDE NOTARIZED LETTER FROM CONTRACTOR INDICATING FOOTER INSTALLED PER ENGINEERED PLANS. |
|
08/27/2018 | SIGN SITE REVIEW | Continued | Reviewed resubmittal received by email. Needs 4 examinations for SDRC: increased height of pole sign no pole covers increased sign area for pole sign (110 square feet) 100 sqft main cabinet and 10 sq ft side arm cabinet bottom cabinet is double faced and perpendicular to 100 sqft main cabinet = multi sided sign |
|
08/16/2018 | SIGN SITE REVIEW | Correction Required | RE: PROPOSED FREESTANDING SIGN FOR: CAT SCALES AT: 9255 S RITA RD / PILOT TRUCK STOP PERMIT: T18OT00867 REVIEWER: H.THRALL DATE: 8/15/18 1) ACKNOWLEDGED THE PROPOSAL IS A REQUEST FOR A REVIEW FOR A SIGN DESIGN OPTION. SPECIFIC ASPECTS THAT NEED TO BE ADDRESSED VIA THE SIGN DESIGN OPTION (SDO) PROCESS WILL BE NOTED WITH **ASTERISKS** BELOW, AFTER GENERAL PLAN CORRECTIONS. THE FOLLOWING COMMENTS ARE PLAN CORRECTIONS: 2) OUTDOOR LIGHTING CODE: a) OLC 501.3 - NOTE MAXIMUM COLOR TEMPERATURE OF INTERIOR ILLUMINATED SIGN IS 4400K. BOTH CABINETS 3) ELECTRICAL a) NEC 600 - ID WHERE POWER IS PROVIDED TO THE SIGN b) NEC 600 - ID SHUT OFF SWITCH - FOR BOTH CABINETS? OR DOES EACH HAVE IT'S OWN? SHOW. c) ASSUME SMALLER CABINET IS LIT. PROVIDE VOLTS, AMPS, CIRCUITS, LIGHTING TYPE - OR CLARIFY IF NOT LIT. 4) STRUCTURAL - ENGINEERING ACKNOWLEDGED, BUT WILL NOT BE REVIEWED FURTHER UNTIL AFTER SDRC PROCESS, OTHERWISE REVIEW FEES APPLY. SHOULD THE PROPOSAL BE APPROVED BY SDRC, PROVIDE: a) NOTE CONNECTION TO CABINET FROM POLES b) SHOW SMALLER CABINET CONNECTION SIGN STANDARDS: UDC 7A 10.2. a) **SIGN HEIGHT EXCEEDS A POLE SIGN** b) **SIGN AREA EXCEEDS A POLE SIGN** c) **NO POLE COVERS SHOWN FOR THIS SIGN** d) **SIGN HAS TWO CABINETS, ONE PERPENDICULAR TO THE OTHER, WITH MULTIPLE (MORE THAN TWO) FACES.** REVISE: SIGN AREA SHOULD INCLUDE THE SMALLER PERPENDICULAR CABINET ON BOTH THE APPLICATION AND THE DRAWING, ALONG WITH THE LARGER CABINET. SPECIFY DISTANCE FROM SOUTH PROPERTY LINE TO SIGN FOR SDRC REVIEW. (VISIBILITY FROM FREEWAY) HEIGHT - IS TAKEN BY AVERAGING THE POINTS 5' AWAY FROM THE SIGN IN 4 CARDINAL DIRECTIONS - FRONT CENTER OF SIGN AND ENDS OF SIGN. HEIGHT ON PLANS IS NOTED FROM "TOP OF CURB"...? FURTHER REVIEW COMMENTS MAY BE FORTHCOMING. OFFICIAL REFERRAL TO SDRC FORTHCOMING, WITH APPLICATIONS FOR A SINGULAR SIGN DESIGN OPTION. |