Permit: T18OT00639

Parcel: 12315158C


Addresses:

1201 E DRACHMAN ST


Inspection Status: Not Ready

Inspection History: COT - ENGR - Signage Final

Permit Number - T18OT00639

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Not Ready

Date Description Inspector Results Comments
10/27/2022 COT - ENGR - Signage Final Not Ready
06/25/2018 COT - ENGR - Signage Final ACONNOR Approved Entered by BFLORES2 -
06/13/2018 COT - ENGR - Signage Final hthrall1 Correction Required Entered by HTHRALL1 - RECEIVED 5/30/18 RE: RETROFIT EXISTING MONUMENT WITH ELECTRIC AND NEW COPY = REVIEWED AS NEW SIGN) + CHANGE COPY ON OTHER MONUMENT PERMIT: T18OT00639 SITE: 1201 E DRACHMAN REVIEWER: H.THRALL 1) NO COMMENTS FOR CHANGE COPY PROPOSAL FOR FLAT GRAPHICS ON 32 SQFT MONUMENT. 2) FREESTANDING SIGN ON DRACHMAN IS ACTUALLY A LOW-PROFILE TYPE SIGN, GIVEN CONSTRUCTION SPECS. PLEASE: a) REVISE APPLICATION TO ID SIGN TYPE CORRECTLY b) LABEL DRAWINGS AS SUCH 3) ON LOW-PROFILE SIGN - CALL OUT ALL ELECTRICAL WORK TO BE DONE. INDICATE WHERE POWER SOURCE IS TO COME FROM FOR THIS SIGN AND SHOW IT HAS A DEDICATED CIRCUIT PER NEC. 600. a) PROVIDE VOLTS, AMPS, CIRCUITS LISTED (NEC.600) b) PROVIDE U.L. NOTATION AND LIGHTING MANUFACTURER (NEC.600) c) IF NOT UL LISTED, AN INTERIOR INSPECTION OF THE SIGN IS REQUIRED AND A FEE IS ASSOCIATED. d) SHOW SHUT OFF SWITCH AT SIGN (NEC.600) e) FURTHER REVIEW COMMENTS MAY BE FORTHCOMING 4) STRUCTURAL ASPECT - a) DEMONSTRATE IF INTERIOR IS HOLLOW CURRENTLY TO RETROFIT WITH LIGHTING AND PUSH THRU LETTERING. b) NOTE HOW SIGN ALTERATION TO OCCUR (I.E. UNDO BOLTS, CARVE LETTER SPACES 0R SAW/CUT, WELD, ETC). NOTE - ON SITE WELDING REQUIRES ENGINEERING CALCULATIONS AND SPECIAL INSPECTION). 5) CALCULATE SIGN AREA BY BOXING RAISED WORDS ON THIS WALL-LIKE STRUCTURE AND ENSURE NOT EXCEEDING 18 SQFT. 6) PROVIDE DIMENSION OF 2' MINIMUM RUNNING FULL LENGTH OF THE SIGN UNDER THE BOTTOM LETTERING FOR LOW-PROFILE DESIGN PURPOSES. 7) PROVIDE HEIGHT AS TAKEN FROM TOP OF LETTERING TO 5' AWAY FROM SIGN, MEASURED EAST, WEST AND SOUTH, INDICATE LOWEST POINT. (PER UDC. 7A.6.5) 8) PROVIDE SETBACK TO SIGN AS TAKEN FROM LEADING EDGE OF CURBT TO SIGN DESIGN/LETTERING/LOGO - CHECK FORMER SITE PLAN AND FORMER DRAWING FOR ORIGINAL CONSTRUCTION. EXCLUDE ADDRESS COLUMN. PLEASE EMAIL CORRECTIONS TO HEATHER.THRALL@TUCSONAZ.GOV OR CONTACT THAT EMAIL AS WELL FOR ANY QUESTIONS. FORMER PERMITS CAN BE FOUND ON LINE UNDER THE SAME ADDRESS AT TUCSONAZ.GOV/PDSD/PRO
07/20/2018 COT - ENGR - Signage Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 -