Inspection History Details
Inspection Status: Passed
Inspection History: COT - ENGR - Signage Final
Permit Number - T18OT00610
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2019 | COT - ENGR - Signage Final | DROBERTS | Approved | Entered by DROBERT5 - |
11/14/2018 | COT - ENGR - Signage Final | DROBERTS | Partial Approval | Entered by DROBERT5 - LOOK OVER THE SITE, THE CREWS ARE PREPARING THE WALL FOR THE GROUT PLACEMENT THIS MORING WITH THE INSTALLATION OF THE INBEDS TO BE UTILIZED AT A LATER DATE. |
06/20/2018 | COT - ENGR - Signage Final | hthrall | Approved | Entered by HTHRALL1 - SEVERAL CONDITIONS ADDED TO PERMIT, INCLUDING SPECIAL INSPECTIONS. |
06/13/2018 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - RESUBMITTAL RECEIVED FOR REVIEW, INCLUDING SOILS REPORT, SPECIAL INSPECTION FORMS AND PLAN DOCUMENTS. |
06/08/2018 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - Submitted 5/25/18 RE: FREEWAY SIGN REVIEW FOR: THE LANDING DEVELOPMENT SITE: 1050 W IRVINGTON RD PERMIT: T18OT00610 REVIEWERS: H. THRALL (SIGNS) E. NEWCOMB (STRUCTURAL) DAN SANTA CRUZ (ELECTRIC/OUTDOOR LIGHTING CODE) AMENDED NOTATION 6/8/18: ZONING ADMINISTRATOR, RUSSLYN WELLS, CONCURS PRIOR DETERMINATION APPLIES, PER 5/22/18 REVIEW. FREEWAY SIGN PRESUBMITTAL: 5/16/18 SIGNS REVIEW (2nd Submitted items reviewed 6/8/18), thus **AMENDED COMMENTS AS FOLLOWS**: 1) SIGN CODE ADMINISTRATOR DETERMINATION DATED 12/24/15 APPLIES TO THIS PROJECT. 2) DRAWINGS FOR SIGN STRUCTURE ARE BOTH SUBMITTED SHEETS SP.2, THEN CS-1 TO CS-6, PLUS ENGINEER'S SET. UNDERSTOOD ENGINEER'S SET ARE PREPARED FOR STRUCTURAL EVALUATION. 3) Electric is approved. 4) Outdoor lighting code - a) 403.5.1 provide timer / note location, **(understood will be on adjacent pedestal, will add to plan - per contractor 6/8/18)** b) 501.3, specify translucent panels - no clear panels ever on this sign, **(comment is actually addressed on sheet CS-1, notes 1 & 2 for aluminum panel construction with routed copy and push thru letters. Contractor will provide night view on plan to complement notes.)** c) 501.3.2. color temperature cannot exceed 4400k per light source - plan exceeds that. 5) Structural calcs appear in good standing (Eric). a) Provide soil report per calcs **(contractor provided 6/8/18 for review)** b) ID frame on the structural support in the engineering in other drawings **(special inspection to occur in shop by engineer with sealed letter with dimensioned/construction of framework, per structural review and contractor understanding.)** c) coordinate drawing dimensions throughout the set. **(engineer inspections to verify shop and field per structural review and contractor understanding.)** 6) **: Remove sheet A2.1, as it does not match current dimensions in submittal set, understood it was meant to show sewer easement area in relation to sign. Instead, in sheet SP.2., bottom section aerial view, label sewer easement, as the above side view shows aerial occupation of the easement and a dimension of the easement width.** 7) ** - Heights - check heights among drawings - there's differences of up to 1 foot between diagrams. **A) PROVIDE STATEMENT ON SHEETS CS-2 & CS-3 THAT "FREEWAY SIGN HEIGHT WILL NOT EXCEED 48' FROM ELEVATION OF I-10 TRAVEL LANE CLOSEST TO SITE - EXIT LANE PER 12/24/15 SITE DETERMINATION." **B) UNDERSTOOD HEIGHT WILL BE SHOP VERIFIED OF FRAMING DIMENSIONS/CONSTRUCTION WITH SEALED ENGINEER'S INSPECTION LETTER PROVIDED, D. BINGHAM, P.E. **C) IN ADDITION, UNDERSTOOD FREEWAY SIGN MASONRY BASE TO BE MARKED BY JEFF HUNT, P.E. WITH I10 TRAVEL LANE ELEVATION FOR CONSTRUCTION AND ASSEMBLY NO GREATER THAN 48' ABOVE THAT MARK. (SEE DETERMINATION FOR I-10 TRAVEL LANE SPECIFICATION TO THIS SITE.) JEFF HUNT TO PROVIDE SEALED LETTER OF MARKING, AND INSPECTOR TO OBSERVE IN FIELD. 8) **Acknowledged sign to be on private property with setback dimension from property line provided on two sheets. B) Per 7A.6.7. SETBACK: Provide setback from freeway travel lane closest to site per determination - dimension 20' minimum, and dimension distance from edge of same freeway travel lane to property line for inspection purposes. (Mark property line in field for verification at inspection given close proximity to property line.) 9) **: Acknowledged sign area notation at 360 sqft on surface maximum at any time. Zoning Administrator concurs with notation. 10) Staff in receipt of email dated 5/18/18 from Pima County Development Services for allowed aerial occupation of freeway sign over Pima County Sewer easement. 11) Have Daniel Bingham, P.E., list name of qualified special inspector on special inspection form. 12) Sheet SP.1., 7A.6.2.A, 7A.6.2.D., 7A.6.9, 7A.6.9.E, Provide street dimensions (for sign area derivatives). Acknowledged it is clear to reviewer due to site size the proposed freeway sign area of 360 square feet has sufficient frontage off I-10 for allowance of that sign area, which is maximum freeway sign area display. The street frontage length notations are for reference of and future sign area calculations and freestanding or additional freeway sign placement. 13) Please note, further comments may be forthcoming, depending upon responses provided. |
06/06/2018 | COT - ENGR - Signage Final | hthrall | Continued | Entered by HTHRALL1 - Submitted 5/25/18 RE: FREEWAY SIGN REVIEW FOR: THE LANDING DEVELOPMENT SITE: 1050 W IRVINGTON RD PERMIT: T18OT00610 REVIEWERS: H. THRALL (SIGNS) E. NEWCOMB (STRUCTURAL) DAN SANTA CRUZ (ELECTRIC/OUTDOOR LIGHTING CODE) AMENDED NOTATION 6/8/18: ZONING ADMINISTRATOR, RUSSLYN WELLS, CONCURS PRIOR DETERMINATION APPLIES, PER 5/22/18 REVIEW. FREEWAY SIGN PRESUBMITTAL: 5/16/18 SIGNS REVIEW: 1) SIGN CODE ADMINISTRATOR DETERMINATION DATED 12/24/15 APPLIES TO THIS PROJECT. 2) DRAWINGS FOR SIGN STRUCTURE ARE 3) Electric is approved. 4) Outdoor lighting code - a) 403.5.1 provide timer / note location, b) 501.3, specify translucent panels - no clear panels ever on this sign, c) 501.3.2. color temperature cannot exceed 4400k per light source - plan exceeds that. 5) Structural calcs appear in good standing (Eric). a) Provide soil report per calcs b) ID frame on the structural support in the engineering in other drawings c) coordinate drawing dimensions throughout the set. 6) Revise sheet A2.1 from Bourn to just keep the sewer easement in there, aerial and side view for comparison and remove the sign dimensions above ground because it doesn't mesh with the other drawings nor the engineer's drawing. 7) Heights - check heights among drawings - there's differences of up to 1 foot between diagrams. 8) AMENDEDED COMMENT 6/8/18: Acknowledged the sign is to be on private property with the setback notation provided on two sheets from property line. Provide setback from freeway travel lane closest to site per determination - dimension 20' minimum, and dimension distance from edge of travel lane to property line for inspection purposes. 9) AMENDED COMMENT 6/8/18: Acknowledged sign area notation at 360 sqft on surface maximum at any time. Zoning Administrator concurs with notation. 10) Staff in receipt of email for aerial occupation of sign over Pima County Sewer easement. 11) Further review comments forthcoming. |
01/16/2019 | COT - ENGR - Signage Final | DROBERTS | Approved | Entered by DROBERT5 - |
12/11/2018 | COT - ENGR - Signage Final | DROBERTS | Partial Approval | Entered by DROBERT5 - FINAL NOT TO BE GIVEN TILL ALL SIGN WORK HAS BEEN COMPLETED FOR THIS PERMIT. FIELD VERIFICATION OF ELECTRICAL WILL NEED TO BE COMPLETED ONCE A SET OF REVISED DRAWINGS HAS BEEN REVIEWED AND APPROVED. |
12/10/2018 | COT - ENGR - Signage Final | BBENEDON | Not ready for Inspection | Entered by CBELL1 - Chris at 3397786 have paperwork and will reschedule for Tuesday. |
11/13/2018 | COT - ENGR - Signage Final | DROBERTS | Partial Approval | Entered by DROBERT5 - SITE VISIT ONLY, WILL REINSPECT THIS SIGN TOMORROW MORNING FOR GROUT. |
10/15/2018 | COT - ENGR - Signage Final | DROBERTS | Partial Approval | Entered by DROBERT5 - THE CREWS HAVE PLACED THE GROUT FOR THE NEW WALL FULL DEPTH, THEY HAVE STOPPED THE GROUT 3 COURSES DOWN FROM THE TOP OF THE WALL. THIS PORTION OF THE GROUT WILL BE POURED WITH THE SOLID SECTION THAT WILL BE POURED AT A LATER DATE WHEN THEY HAVE THE UPPER STEEL AVAILABLE FOR THE TOP COURSE. THE DRILLING OF THE FOOTER FOR THE NEW INBEDDED AND EPOXY REBAR HAS BEEN WITNESSED AND BEEN INSPECTED BY THE SPECIAL INSPECTOR FOR THIS SITE, REPORTS WILL BE PROVIDED FOR THIS WORK. |
10/05/2018 | COT - ENGR - Signage Final | DROBERTS | Continued | Entered by DROBERT5 - MET ONSITE WITH ROB EAST NAD LOOKED AT THE PAPERWORK THAT HE WILL BE SUBMITTING FOR THIS SIGN AND THE WORK THAT DID NOT GET INSPECTED. HE WILL HAVE HIS ENGINEER OF RECORD STAMP THE REQUIRED DOCUMENTS FOR THE UNSEEN WORK AND WILL SUBMIT IT TO THE SIGN DEPARTMENT FOR THEIR REVIEW AND APPROVAL PRIOR TO CALLING IN ANYMORE INSPECTIONS. HE HAS ADVISED ME THAT THEY WILL BE OPENING THE LOWER BLOCKS IN THE CELLS WHERE THEY WILL BE DRILLING AND PLACING THE EPOXIED REBAR INTO THE FOOTER. HE WILL ALSO PROVIDE THE DOCUMENTS SHOWING THAT THERE IS ENOUGH OF THE FOOTER NOT REQUIRING ANY ADITIONAL CONCRETE FOOTERS TO BE POURED. |
09/17/2018 | COT - ENGR - Signage Final | DROBERTS | Denied | Entered by DROBERT5 - THE EXTERIOR WALL HAS BEEN CONSTRUCTED AND HAS NOT BEEN INSPECTED BY MYSELF FOR EITHER THE FOOTER OR THE CONSTRUCTION AND GROUTING OF THE WALL. I CONTACTED PAUL BLEIER AND ADVISED HIM OF THE FOLLOWING WORK THAT HAS NOT BEEN INSPECTED AT THIS TIME: 1) THE NEW FOOTER WHAT WAS UTILIZED FOR THE PLACEMENT OF THE NEW WALLS. HE ADVISED ME THAT THE REBAR FROM THE OTHER WALL WAS BENT OVER AND PLACED INT THE NEW LOCATION FOR THE NEW WALL. 2) THE CONSTRUCTION OF THE NEW WALL WAS NOT INSPECTED BY MYSELF OR OTHERS PRIOR TO THE PLACEMENT OF THE GROUT, CANNOT VERIFY IN WHAT CELLS THE REBAR HAS BEEN PLACED AND THE HEIGHT OF THE OVERLAP FOR THE REMAINING PORTIONS OF THE WALL. 3) I HAVE ASKED THAT THE ENGINEER OF RECORD STAMP AND SEAL A LETTER OF ACCEPTANCE FOR ALL OF THE WORK THAT WAS NOT WITNESSED BY THIS DEPARTMENT, PRIOR TO THE PLACEMENT OF THE FINAL LIFT OF THE GROUT FOR THIS SIGN. |
08/28/2018 | COT - ENGR - Signage Final | DROBERTS | Partial Approval | Entered by DROBERT5 - OK TO POUR THE FOOTER FOR THIS SITE, THE CREW WILL ADD THE FORMS AS NEEDED PRIOR TO THE PLACEMENT OF THE CONCRETE |
08/27/2018 | COT - ENGR - Signage Final | DROBERTS | Denied | Entered by DROBERT5 - NOT READY AT THIS TIME FOR THIS INSPECTION. THE FOLLOWING COMMENTS HAVE BEEN ADDED TO THE SIGN EXCAVATION LAYOUT FOR THIS PORTION OF THE INSPECTIONS. REMOVE ALL EXCESS SOIL FROM THE TOP OF THE CAISON PRIOR TO POURING THE FOOTER FOR THIS SITE. PROVIDE ME WITH A PHOTO THAT SHOWS ALL OF THE SOIL HAS BEEN REMOVED PRIOR TO PLACING THE CONCRETE. |