Case: T18DV07929

Parcel: 107111710


Addresses:

210 W BLACKLIDGE DR


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T18DV07929

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
12/12/2018 INSP - INITIAL CODE ENFORCMENT Approved Assisted Inspector Gonzales. Found electrical hazards at the service. Main breaker missing manufactures hold down, grounding electrode system not properley connected. Missing gas & water bonds. Interior has grounded receptacle on non-grounded circuits. Using excess loads for space heaters.
12/12/2018 INSP - INITIAL CODE ENFORCMENT Approved UPON INSPECTION CODE ENFORCEMENT HAS FOUND THE FOLLOWING:
EXTERIOR:
GRASS AND WEEDS EXCEEDS 6 INCHES IN HEIGHT ON THE PROPERTY. THERE IS TRASH AND DEBRIS ON THE PROPERTY.
PLUMBING: PVC PIPING AND COOLER LINES ARE LOOSE AND NOT BEING SUPPORTED.
STRUCTURE: BUILDING SHEATHING IS DETERIORATED
ELECTRICAL: VERIFICATION OF GROUNDING ELECTROID SYSTEM AND THE WATER BOND TO THE EARTH. SERVICE PANEL IS NOT LABEL TO THE ADDRESS IT PROVIDES ENERGY. IMPROPER FITTING DEAD FRONT NOT MADE FROM THE MANUFACTURER OF THE PANEL. MAIN BREAKER IS MISSING THE MANUFACTURER HOLD-DOWN.

INTERIOR:
MISSING FUNCTIONAL SMOKE DETECTORS, ROACH AND INSECT INFESTATION. THE PERMANENT HEAT SOURCE TO THE DWELLING IS INOPERABLE, THE OUTSIDE FLUE TO THE FURNACE NEEDS TO BE PROPERLY SUPPORTED.
PLUMBING: KITCHEN FAUCET DOES NOT EMIT COLD WATER, COLD WATER SHUT OFF IS INSTALLED ABUTTING TO HOT WATER VALVE NOT ALLOWING SPACE TO TURN THE VALVE IN ANY DIRECTION. THE BATHROOM TUB WATER FIXTURES LEAK AND HAVE MISSING COVERS OR SPOUTS. INSUFFIECENT PRESSURE ON THE HOT SIDE OF THE BATHTUB VALVE.
STRUCTURE: WINDOWS ARE MISSING THE LOCKING MECHANISM AND WINDOW'S SEALS. BOTH THE FRONT AND REAR EXIT DOORS ARE MISSING THE WEATHER STRIPPING AND PART OF THE DOOR JAM.
ELECTRICAL: AN ADEQUATE RECEPTACLE IS NEEDED FOR THE STOVE OR VERIFICATIONS FROM THE MANUFACTOR THAT THE POWER STRIP CORD IS ALLOWED FOR ITS CURRENT USE.