Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2019 | INSP - FOLLOW UP CODE ENFORCE | Approved | D.D.O. HAS BEEN APPROVED FOR THE 2 STORY DWELLING (T18SA00556) PERMIT T18CM09245 HAS BEEN ISSUED AND PENDING COMPLETION OF INSPECTIONS CLOSING CASE. PROPERTY OWNER HAS COMPLIED WITH NOTICE OF VIOLATION TO OBTAIN AND SECURE PERMITS. | |
| 02/12/2019 | INSP - FOLLOW UP CODE ENFORCE | Approved | DDO-18-118 HAS BEEN APPROVED ONCE PERMITS HAVE BEEN OBTAIN IN ISSUE STATUS CASE WILL BE CLOSED. | |
| 12/21/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | T18CM09245 PERMIT SHOWS: 12/19/2018 NICHOLAS ROSS ZONING REVIEW Reqs Change P&DS TRANSMITTAL FROM: Nick Ross Lead Planner PROJECT: T18CM09245 443 W. 41st St. Addition and Permit Existing Structure TRANSMITTAL: December 19, 2018 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The applicant is permitting an existing structure on the south side of the property and proposing a new addition. The height of the structure on the south side is 19'2" and has a setback of 5'0". The required setback is 12'6". The new addition is proposed to be 20'10" with a setback of 8'0" on the west side of the property and 4'6" on the east side. The required setback is 13'7". DDO is required. |
|
| 11/29/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | T18CM09245 HAS BEEN APPLIED FOR REMODELING/ADDITION ON THE PROPERTY. | |
| 09/21/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE INSPECTION | |
| 09/21/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | REVIEWED LAST APPROVED PLAN FOR THE PROPERTY, SHOWS ONLY A 26X 29 BUILDING AND A 20X10 SHED AT THE REAR. SHED HAS BEEN EXTENED TO BEING USED AS A LIVING SPACE WITH UTILITIES AND PLUMBING WITH 2ND FLOOR ABOVE BEING USED ALSO AS A LIVING SPACE. ANOTHER UN PERMITTED STRUCTURE HAS BEEN CONSTRUCTED WITH A 2ND FLOOR WITH UTILITIES IN BETWEEN THESE STRUCTURES, THE ELECTICAL SERVICE PANEL IS SHIFTING THE RISER IS NOT BEING ANCHORED THE ADOBE WALL THE SERVICE PANEL IT IS ATTACHED TO IS DETERIORATED WITH POSSIBLITIES OF SHIFTING. POWER IS BEING TERMINATED DUE TO THESE CONDITIONS AND OTHER EXTENDED MULTIPLE CODE VIOLATIONS. POWER HAS BEEN CUT AT THE POLE BY T.E.P AND A CLEARANCE HAS BEEN PLACED TO PREVENT ENERGIZING PROPERTY WITHOUT PROPER INSPECTIONS TO ENSURE A SAFE ENVIROMENT |
|
| 09/20/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | UPON INSPECTION MET PROPERTY OWNER ON SITE, AND IS AWARE OF MEETING ON SITE ON 9/21/2018 AT 9AM TO DETERMINE SITE IS UNFIT TO OCCUPY. OWNER HAS BEEN NOTIFIED IN PERSON HOME HAS BEEN BUILT WITHOUT PERMITS AND ADVISED TO RELOCATE DUE TO POSSIBLE HAZARD. |