Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T18CM10033
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2019 | FRAMING | Approved | ||
04/02/2019 | FRAMING | Denied | 1. Remove mesh staples behind home runs 2. Boca plate at Gas main top plate 3. Fasten powder room toilet flange to floor and master bath toilet flange to floor 4. Boca plate top plates at 3” abs over bore and stud shoe same abs at stud over bore 5. Boca plate cut out bearing top plate at gas stove vent-backside 6. Stud shoe and boca on dining east wall at 2” abs over bored 7. Seal top south side of the main second floor duct chase 8. Replace master shower rough sawn surround backer pieces with #2 framing studs |