Permit: T18CM09936

Parcel: 141020180


Addresses:

10220 E ENCINAS TR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T18CM09936

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/21/2019 FRAMING Approved
03/19/2019 FRAMING Denied Need to fire block at garage door chase horizontal openings
Cut tar paper back away from B vent at water heater
Support 4 gang switch in den
Remove H25 clips on 2 point bearing trusses on east wall of den
Move pex in den ceiling 12” from can lights
Missing outlet on west kitchen wall
Missing anchor bolt nuts at various locations throughout
Roof truss north of hallway entry in living room correct bearing point as needed
Shim bearing point of truss south of garage hallway in living room
Support 4 gang switch in living room
Need to put boca plate over 2” abs over bore in top plate in master bathroom
No pressure on potable water