Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T18CM09934
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/01/2019 | MECHANICAL - INTERMEDIATE | Approved | Fire foam around hot water heater vent pipe at all levels Completely nail boca plates at 2” drain lines in front living room Move all pex lines at least 12” away from can lights Properly secure 4 gang light switch box’s in living room/kitchen (2 total) Provide blocking on 3 sides of jumper duct boots between living room and office Completely nail boca plate at 3” drain line next to sliding down to backyard Provide blocking on 3 sides of jumper duct boots between hallway and bedroom upstairs Provide blocking on 3 sides of duct boot in upstairs bathroom Potable water had no air pressure in the lines gauge read 0 psi Missing light in 2nd bathroom over tub and cut romex line at gfci Broken can light at top of stairs and missing can light above stair landing |