Permit: T18CM09934

Parcel: 141020180


Addresses:

10236 E ENCINAS TR


Inspection Status: Denied

Inspection History: FRAMING

Permit Number - T18CM09934

Inspection Description - FRAMING

Inspection Status - Denied

Date Description Inspector Results Comments
04/03/2019 FRAMING Denied Fire foam b vent escutcheons at all penetrations
04/03/2019 FRAMING Approved
04/01/2019 FRAMING Denied Fire foam around hot water heater vent pipe at all levels
Completely nail boca plates at 2” drain lines in front living room
Move all pex lines at least 12” away from can lights
Properly secure 4 gang light switch box’s in living room/kitchen (2 total)
Provide blocking on 3 sides of jumper duct boots between living room and office
Completely nail boca plate at 3” drain line next to sliding down to backyard
Provide blocking on 3 sides of jumper duct boots between hallway and bedroom upstairs
Provide blocking on 3 sides of duct boot in upstairs bathroom
Potable water had no air pressure in the lines gauge read 0 psi
Missing light in 2nd bathroom over tub and cut romex line at gfci
Broken can light at top of stairs and missing can light above stair landing