Permit: T18CM09861

Parcel: 11106175A


Addresses:

3727 E GLENN ST #G


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T18CM09861

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/28/2018 PLUMBING - FINAL Approved
12/27/2018 PLUMBING - FINAL Correction Required T&P drain line
Cap Smitty pan if not draining to outdoors
Secure gas lines
6” Clearance req for H/C appliance connector lines
B Vent to slope 1/4" per foot towards vent outlet for gravity venting
B Vent to have 1" Clearance from combustibles at ceiling. Use an approved vent thimble
12/21/2018 PLUMBING - FINAL Denied 1- Shall provide (3 ) sheet metal screws on the water heater draft collar.