Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2019 | PLUMBING - FINAL | Approved | ||
| 09/19/2019 | PLUMBING - FINAL | Denied | 1- Overhead domestic water supply line to the main bathroom shall be insulated due to cold water turns to hot because it is located in attic space. 2- Shall cap off the water heater drain pan outlet | |
| 09/05/2019 | PLUMBING - FINAL | Denied | 1- Water heater T & P drain not provided and shall extend and terminate into the drip pan and cap off the pan drain outlet. 2- Shall provide water hammer arrestors for the clothes washer water supply outlets. 3- The flex connector for the Range can not pass thru the wall of the cabinet. This must be hard piped thru the case work. 4- Shall paint the sanitary vent thru roof with. Laytex base paint. 5- The lavatory cold water supply comes out hot for awhile then turns cold after running due to no insulation on piping. 6- Shall remove the painted flex connector at AC Gas pack unit for proper size verification |
|
| 08/30/2019 | PLUMBING - FINAL | Denied | 1- No one home at time of inspection request. | |
| 07/24/2019 | PLUMBING - FINAL | Not ready for Inspection | previous corrections were not addressed at all. Another failed inspection will result in a reinspection fee. | |
| 07/23/2019 | PLUMBING - FINAL | Partial Approval | smoke alarm outside new sleeping area needs to be carbon monoxide as well. Kitchen either needs exhaust fan or hood installed. Water heater either needs disconnect or lock out tag out at panel. T&P piping needs to be installed. | |
| 07/15/2019 | PLUMBING - FINAL | Not ready for Inspection | no access, no one home, no key in lock box. | |
| 03/26/2019 | PLUMBING - FINAL | Not ready for Inspection | currently at intermediate stage not at finals |