10/29/2019 | ROOF NAILING | Approved | ||
09/26/2019 | ROOF NAILING | Partial Approval | PLEASE SUMBIT ROOF TRUSS PLANS FOR APPROVAL PRIOR TO BUILDING FINAL | |
04/09/2019 | ROOF NAILING | Partial Approval | check detail 9 on page 7 missing h2.5’s clips at top and use the correct Simpson hangers on bottom. Check bracing missing on several trusses, install bracing per truss calx. OK to cover roof. | |