Permit: T18CM09434

Parcel: 110081590


Addresses:

4545 E BERMUDA ST

Inspection Status: Approved

Inspection History: RESIDENTIAL INTERMEDIATE

Date Description Inspector Results Comments
10/16/2019 RESIDENTIAL INTERMEDIATE Approved
10/10/2019 RESIDENTIAL INTERMEDIATE Denied 1. Seal small gaps in north furred garage wall fire
blocking with orange foam.
2. Seal all fire blocking penetrations in living space with foam.
3. Seal top of Rheem wall for fire. Suggest using rock wool insulation for such a large opening.
4. Lower gas line pressure test ok. Upper gas line pressure test failed. Redo.
10/07/2019 RESIDENTIAL INTERMEDIATE Correction Required 1-Install stud(s) under. Fireblock supporting I-joist in garage as discussed at roof deck inspection.
2- Fireblocking is missing; at double walls and furr-out walls vertical fireblocking may be required per IRC R302.11#1. 2-Remove or complete wiring buried in furr-out walls.
3-No test on DWV piping.
4-Provide opening for access panel at in line filter and shut off valve in closet.
5-Window by door is not tempered