Inspection History Details
Inspection Status: Passed
Inspection History: COT - LCPL - Plumbing Intermediate
Permit Number - T18CM09411
Inspection Description - COT - LCPL - Plumbing Intermediate
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/11/2019 | COT - LCPL - Plumbing Intermediate | JCLAXTON | Approved | Entered by DMERANZ1 - |
12/06/2019 | COT - LCPL - Plumbing Intermediate | TVALENCIA | Denied | Entered by DMERANZ1 - 1- Shall seal all electric conductors that penetrate the top plates. 2- Shall provide (3) sided blocking on the second floor forced air vents. 3- Shall provide a clean out at the 3 inch soil stack. 4- Shall secure the horizontal pex water lines every 32 inches. |