Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - T18CM09411
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | ESTEVENS | Approved | Entered by DMERANZ1 - |
12/11/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | JCLAXTON | Denied | Entered by DMERANZ1 - See 1035. Mechanical, electrical, plumbing all AP. |
12/06/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | TVALENCIA | Denied | Entered by DMERANZ1 - 1- Shall seal all electric conductors that penetrate the top plates. 2- Shall provide (3) sided blocking on the second floor forced air vents. 3- Shall provide a clean out at the 3 inch soil stack. 4- Shall secure the horizontal pex water lines every 32 inches. |