Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/04/2019 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
|
| 12/21/2018 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
missing gable bracing. Missing 4 by 8 beam on east side under glulam. Missing 4 by 4’s under 4 by 8’s. New rafters on the west side of house call for 2 by 12s that is not what is installed. Detail around 5 by 12 glulam and lup 26 metal hangers is not what is installed. Missing ridge blocking. Missing blocking in several places according to the drawings. Stopped inspection. Recommend revising the drawings |