Permit: T18CM09116

Parcel: 107121290


Addresses:

45 E LAGUNA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/29/2018 PLUMBING - FINAL Approved
11/21/2018 PLUMBING - FINAL Denied 1- Burial depth is a minimum of 12 inches, check depth by meter location.
2- Shall provide double wall flu vent piping at extensions on roof for the water heater and furnace.
3-Shall remove themechanical tape around the water heater flu vent.
4- Shall provide sediment traps for the water heater and furnace gas supplys.
5- Shall seal the exterior gas penetration.
6- Shall provide a water heater drip pan and terminate the T &P drain into the pan
11/20/2018 PLUMBING - FINAL Not ready for Inspection 1- Contractor canceled the inspection request.