Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2018 | PLUMBING - GAS PRESSURE TEST | Approved | ||
| 11/21/2018 | PLUMBING - GAS PRESSURE TEST | Denied | 1- Burial depth is a minimum of 12 inches, check depth by meter location. 2- Shall provide double wall flu vent piping at extensions on roof for the water heater and furnace. 3-Shall remove themechanical tape around the water heater flu vent. 4- Shall provide sediment traps for the water heater and furnace gas supplys. 5- Shall seal the exterior gas penetration. 6- Shall provide a water heater drip pan and terminate the T &P drain into the pan |
|
| 11/20/2018 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | 1- Contractor canceled the inspection request. |