Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T18CM09049
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2018 | PLUMBING - INTERMEDIATE | Approved | Remodel Apartment building five units total. Kitchen remodel and add stackable laundry in kitchen. unit 140 |
|
11/29/2018 | PLUMBING - INTERMEDIATE | Correction Required | Contractor see same corrections as unit 8 | |
11/27/2018 | PLUMBING - INTERMEDIATE | Denied | 1- Shall provide a mission specialty coupling for ABS piping. No hub couplings not approved for plastic piping. 2- unit 129 Clothes washer trap arm can not have a vertical offset. |