Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T18CM08693
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/03/2019 | PLUMBING - INTERMEDIATE | Approved | ||
03/28/2019 | PLUMBING - INTERMEDIATE | Partial Approval | Units in need of corrections; unit 3112 back pitch in bathroom to garage vent, double top plate cut too wide on first floor, engineering fix required. Unit number 3111, double top plate cut two wide engineering fix required. | |
03/26/2019 | PLUMBING - INTERMEDIATE | Cancelled | Cancel by contractor | |
03/22/2019 | PLUMBING - INTERMEDIATE | Denied | 1- Shall provide shield plates on all plumbing waste and vent lines that are within a 11/2” from the edge of plates. 2- Shall install the combination tee wyes horizontally to the 3 inch soil lines for the shower trap arms. 3- Shall provide a block or strap on all horizontal waste and vent line every 5 feet. 4 - Re test the DWV system. |
|
03/21/2019 | PLUMBING - INTERMEDIATE | Not ready for Inspection | cancel by contractor | |
03/19/2019 | PLUMBING - INTERMEDIATE | Cancelled | Cancel by contractor |