Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18CM08491

Parcel: 140325720


Addresses:

3977 E BRADDOCK DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T18CM08491

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/27/2018 EXT METAL CLIPS/EXT SHEATHING Approved
12/26/2018 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection 1. need another 2by under beam in garage west side.
2. Remove blocking under mechanical trusses stopping deflection.
3. Missing 2by4 bracing on mechanical trusses.
4. Finish nailing off the roof.
5. Need ladder set up and secured to inspect roof.
6. Missing H2.5’s over stairs.
7. Make sure shear transfer wall behind stairs meets one of the conditions on the detail.
8. Floor trusses need to be shimmed at middle bearing wall.
9. Shear walls loose at back of house.
10. Shear wall behind stairs needs to be re-nailed where shiners are.
11. Shear walls missing on second floor
12. Stopped inspection