Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 10/29/2018 |
ELECTRIC - RECONNECT |
|
Approved |
|
| 10/12/2018 |
ELECTRIC - RECONNECT |
|
Not ready for Inspection |
need smoke alarms in bedrooms 3 foot away from Supply Air. Need smoke carbon alarm in hallway outside of sleeping area. Need cover plates on all switches and receptacles throughout the house including sheds and storage areas. Need receptacles that are broken replaced. Need weatherproof covers on exterior receptacles that are missing them including shed. Need door on sub panel in back patio storage. Three prong system needs first receptacle on circuit to be GFCI protected in kitchen and bathrooms |