Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T18CM07944
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2018 | ROOF NAILING | Approved | ||
11/15/2018 | ROOF NAILING | Denied | 1)Roof nailing missed many rows, bird boards, and out riggers. 2)Several hold downs need nailing up both studs through OSB. 3) Missed RSP-4 @ Top plate west of Hood Vent. 4) Nail all king studs in front of Garage door shear panels. 5) FHA strap needed outside top plate over notch at HVAC lines. 6) Bang plate needed exterior Master Bath for ABS bottom plates. |