Permit: T18CM07563

Parcel: 11705033A


Addresses:

340 E 6TH ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
07/14/2021 REINFORCED MASONRY PRE-GROUT Approved AP
03/27/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/24/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/23/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/20/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/19/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/17/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/16/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/12/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/11/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/10/2020 REINFORCED MASONRY PRE-GROUT Partial Approval west stair and elevator chase redone at top for misplaced bolts. now ok to grout to top out 60'8"
03/09/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/06/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
03/04/2020 REINFORCED MASONRY PRE-GROUT Partial Approval West stair/elevator shaft ok to grout to top out at 60' 8"
02/28/2020 REINFORCED MASONRY PRE-GROUT Partial Approval East stair walls ok to grout to top at 60’8"
Stems for garbage dump area ok to grout 1st lift.
02/25/2020 REINFORCED MASONRY PRE-GROUT Partial Approval Ok to grout 52’ 8" to 58’ 4" on the east stair tower.
02/14/2020 REINFORCED MASONRY PRE-GROUT Partial Approval Both stair and elevator chase ok to grout to 45" 4"
02/13/2020 REINFORCED MASONRY PRE-GROUT Partial Approval GL 1 @ B3 to A3 and A3 @ 1 to 3.5 - ok to grout stems to 2nd lift.
02/07/2020 REINFORCED MASONRY PRE-GROUT Partial Approval Ok to grout north wall 1st lift from A - 5 to3.5
Ok to grout E W stair/ elevator shafts 34’8" to 40’
02/06/2020 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
02/04/2020 REINFORCED MASONRY PRE-GROUT Partial Approval 2nd lift of walls ok to grout.
A - 5 to 3, B.2 - 5 to 1

E W stairs and elevator ok to grout to 34’ 8"
01/28/2020 REINFORCED MASONRY PRE-GROUT Partial Approval SHEARWALLS AT GL 2, 3, 4 - A -B.2 OK TO GROUT 1ST LIFT
01/24/2020 REINFORCED MASONRY PRE-GROUT Partial Approval Elevator shafts in east building ok to grout to 24’