Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18CM07233

Parcel: 305090910

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T18CM07233

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/27/2018 PLUMBING - INTERMEDIATE Approved
11/21/2018 PLUMBING - INTERMEDIATE Not ready for Inspection
11/16/2018 PLUMBING - INTERMEDIATE Denied 1) Seal 2 car Garage front chases.
2) Block combustion and relief vents.
3) Replace damaged H2O heater B-vent.
4) Correct swaled top plates above cut studs at garage relief vents.
5) West entry top plates need fire foam.
6) Rebuild Tub diverter wall in east hall bath.
7) Move N. Kitchen counter GFCI to window stud.
8) S.E. Bedroom- staple romex out of box.
9) Fire foam N. Kitchen & S.E. bedroom top plates.
10) Secure Master BR. 4 gang switch box.
11) Move PEX from master shower can light, need 12" clearance.
12) Master BR. ABS needs FHA & stud shoe.
13) Laundry recept needs to be tied into circuit.
14) Nail off dryer FHA strap.