Permit: T18CM07233

Parcel: 305090910

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T18CM07233

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/27/2018 FRAMING Approved
11/21/2018 FRAMING Not ready for Inspection
11/16/2018 FRAMING Denied 1) Seal 2 car Garage front chases.
2) Block combustion and relief vents.
3) Replace damaged H2O heater B-vent.
4) Correct swaled top plates above cut studs at garage relief vents.
5) West entry top plates need fire foam.
6) Rebuild Tub diverter wall in east hall bath.
7) Move N. Kitchen counter GFCI to window stud.
8) S.E. Bedroom- staple romex out of box.
9) Fire foam N. Kitchen & S.E. bedroom top plates.
10) Secure Master BR. 4 gang switch box.
11) Move PEX from master shower can light, need 12" clearance.
12) Master BR. ABS needs FHA & stud shoe.
13) Laundry recept needs to be tied into circuit.
14) Nail off dryer FHA strap.