Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T18CM07232
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2019 | EXT METAL CLIPS/EXT SHEATHING | Approved | Work is covered; no visible violations. | |
| 09/12/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | main house only. | |
| 05/22/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Shear nailing is good, however roof framing does not match approved plans. Trusses have been replaced by I-joists, which are not shown on plans. Also, center area shows existing 6 in 12 Pitch, that has new I-joists installed at approximately 1/2 in 12 pitch. There are parapet walls not shown on plans. Lastly, joist hangers have no nails into joists; install nails or provide manufacturers installation instructions showing these are not needed. | |
| 05/15/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | No plans on site |