Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18CM07202

Parcel: 305090940

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T18CM07202

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/27/2018 MECHANICAL - INTERMEDIATE Approved
11/16/2018 MECHANICAL - INTERMEDIATE Denied 1) Master bath shower ABS needs FHA.
2) Secure toilet flanges.
3) H2.5 Hip Trusses where needed.
4) Cut tar paper from. B-Vents 1" clearance.
5) Fire foam Master closet & laundry top plates, where penetrations.
6) Move PEX from hallway can light, 12" clearance.
7) Nail off dryer FHA.
8) S.W. Bedroom need cripple studs above window for Girder Truss.
9) Fire foam S. Bedroom chase.