Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T18CM07202
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/27/2018 | MECHANICAL - INTERMEDIATE | Approved | ||
11/16/2018 | MECHANICAL - INTERMEDIATE | Denied | 1) Master bath shower ABS needs FHA. 2) Secure toilet flanges. 3) H2.5 Hip Trusses where needed. 4) Cut tar paper from. B-Vents 1" clearance. 5) Fire foam Master closet & laundry top plates, where penetrations. 6) Move PEX from hallway can light, 12" clearance. 7) Nail off dryer FHA. 8) S.W. Bedroom need cripple studs above window for Girder Truss. 9) Fire foam S. Bedroom chase. |