Permit: T18CM07202

Parcel: 305090940

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T18CM07202

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/27/2018 FRAMING Approved foam South bedroom Chase, finish nailing FHA plate, move can for clearances in Hall.
11/16/2018 FRAMING Denied 1) Master bath shower ABS needs FHA.
2) Secure toilet flanges.
3) H2.5 Hip Trusses where needed.
4) Cut tar paper from. B-Vents 1" clearance.
5) Fire foam Master closet & laundry top plates, where penetrations.
6) Move PEX from hallway can light, 12" clearance.
7) Nail off dryer FHA.
8) S.W. Bedroom need cripple studs above window for Girder Truss.
9) Fire foam S. Bedroom chase.