Permit: T18CM06715

Parcel: 136244380


Addresses:

6938 E DAVID DR

Inspection Status: Approved

Inspection History: RESIDENTIAL INTERMEDIATE

Date Description Inspector Results Comments
01/08/2019 RESIDENTIAL INTERMEDIATE Approved Includes all intermediates. Ok to insulate, rock and tape.
01/04/2019 RESIDENTIAL INTERMEDIATE Correction Required Gas air test Ok
Exhaust fans require vents to outside
Staple Romex within 12” of all electrical boxes
12/27/2018 RESIDENTIAL INTERMEDIATE Partial Approval 1. Roof ok to dry in.
2. Elec almost complete and ok.
3. Gas at 7.5 lbs for 2 weeks. Check again
4. Wall sheathing ok to mesh.
5. Fire stop penetrations and drop soffits.
6. New ducts ok. Need vent fans in place.