Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T18CM06715

Parcel: 136244380


Addresses:

6938 E DAVID DR


Inspection Status: Approved

Inspection History: RESIDENTIAL INTERMEDIATE

Permit Number - T18CM06715

Inspection Description - RESIDENTIAL INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/08/2019 RESIDENTIAL INTERMEDIATE Approved Includes all intermediates. Ok to insulate, rock and tape.
01/04/2019 RESIDENTIAL INTERMEDIATE Correction Required Gas air test Ok
Exhaust fans require vents to outside
Staple Romex within 12” of all electrical boxes
12/27/2018 RESIDENTIAL INTERMEDIATE Partial Approval 1. Roof ok to dry in.
2. Elec almost complete and ok.
3. Gas at 7.5 lbs for 2 weeks. Check again
4. Wall sheathing ok to mesh.
5. Fire stop penetrations and drop soffits.
6. New ducts ok. Need vent fans in place.