Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/15/2020 | REINFORCED MASONRY PRE-GROUT | Approved | ||
| 01/07/2020 | REINFORCED MASONRY PRE-GROUT | Denied | Wall is already grouted, anchor bolts for ledger board are recessed to far into the wall to attach a ledger board. | |
| 12/06/2019 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Missing anchor bolts 32" O.C. per detail #3. Missing horizontal joint re-inforcement 16" O.C. per detail #2. Beam saddles appear to be misaligned. Re-inspection fee applies. |
|
| 12/05/2019 | REINFORCED MASONRY PRE-GROUT | Denied | Called phone number listed 2 times, 1113 am, 1140 am. Knocked on door, young lady answered said she didn’t live there and had no plans. Recall. | |
| 11/22/2019 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Bond beam ok Need anchor bolts for ledger inspected before grout. |
|
| 11/19/2019 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Ok to grout west block door wall and SE column. Have east block wall plan revised to show change from flat roof to gable roof and the new rebar and anchor bolt requirements for this change. |
|
| 11/14/2019 | REINFORCED MASONRY PRE-GROUT | Partial Approval | Ok to grout 1st lift |