Inspection Status: Passed
Inspection History: COT - LCBU - Excavation/Rebar/Zoning
| Date |
Description |
Inspector |
Results |
Comments |
| 12/20/2018 |
COT - LCBU - Excavation/Rebar/Zoning |
BJONES |
Approved |
Entered by CBELL1 - Steel per engineer details
Rebar double Matt #4 Footings #6 12"EW
Matt’s are 8"EW at Ends to 12" EW at Interior per plan
Grounding Electrode Conductors are Cad Welded to rebar
Conduits per specifications and secured in place. Conduits are with steel nipples through concrete.
Special Inspecton by Others |