Permit: T18CM06276

Parcel: 132100820


Addresses:

3249 S IRENE VISTA

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/06/2018 PLUMBING - INTERMEDIATE Approved
10/25/2018 PLUMBING - INTERMEDIATE Not ready for Inspection
10/17/2018 PLUMBING - INTERMEDIATE Correction Required Laundry, trap indoors not outdoors buried in the ditch, add a c/out for the drain line and a vent as required.
#18 ha green tracer wire required at outdoor sewer line from end to end.
Y and 1/8 bend or sweep required at 90’ ABS to clay sewer pipe change in direction.
Test way C/out required at building to sewer line drain pipe
09/14/2018 PLUMBING - INTERMEDIATE Partial Approval MSc. call for drywall nailing inspection and relocate smoke detector outside of closet
test required on all new waste and vent piping
09/13/2018 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/06/2018 PLUMBING - INTERMEDIATE Not ready for Inspection
09/05/2018 PLUMBING - INTERMEDIATE Denied west shower leaking on rough inspection, another failed inspection will result in a re-fee
09/04/2018 PLUMBING - INTERMEDIATE Not ready for Inspection THIS INSPECTION IS FOR ROUGH. LEAK AT EAST TOILET. RE-DO
08/28/2018 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*