Permit: T18CM06117

Parcel: 132091630

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
08/16/2018 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
08/14/2018 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999 #8 ROMEX FROM ROOF WILL NEED CONDUCTORS PROTECTED WHERE THEY ENTER ELECTRICAL LOAD CENTER. PROVIDE PROOF OF 2 GROUND RODS ATTACHED WITH #4CU. WATER AND GAS BONDS REQUIRE GOOD CONDUCTION SO PLEASE REMOVE PAINT, WHERE ATTACHED TO PIPES. SMOKE DETECTORS ARE REQUIRED IN EACH SLEEPING ROOM AND HALLWAY.


*
08/10/2018 ELECTRIC - SERVICE UPGRADE Correction Required 1.) 2 ground rods required or expose existing rods. old/existing #4 connected to unknown 2.) Gas Bond required 3.) Label all breakers in service panel