Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T18CM05701
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/21/2019 | ELECTRIC - FINAL | Approved | ||
10/15/2019 | ELECTRIC - FINAL | Partial Approval | 1- Restroom and Janitors Room located in Area 10 is okay. | |
09/04/2019 | ELECTRIC - FINAL | Partial Approval | 1- Above ceiling is okay in restrooms 414-A, B,C,D,E. Stall B & E will be Accessible at a later time as per the Airport directions. 2- Shall provide accessible signage, fixture caulking and lavatory p-trap and supply wrapping protection. 3- Restroom 176 has the vertical grab bar to high and the Lavatory rim height to high. 4- Room 110 Custodial closet door is okay. 5- Room 136 Accessible Restroom. 1- Water closet shall be located 16 to 18 inches from side wall. 2- Shall provide P-Trap and supply line wrapping. 3- vertical grab is to high. Site 1 1- Scope of Work in site if okay for final. |