Permit: T18CM05239

Parcel: 120087420


Addresses:

732 W OKLAHOMA ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
11/30/2018 MECHANICAL - INTERMEDIATE Approved
07/13/2018 MECHANICAL - INTERMEDIATE Denied 1- white wire for neutral only
2- bushing at disconnect
3- unit data plate not identified
4- condensate not properly terminated
5- condensate not properly supported above roof
6- condensate not coated for U.V. protection
7- all PVC joints to have purple primer prior to glue
8- provide approved truss load calcs as this is not a replacment
9- another failed inspection will result in a re-fee