Inspection History: BUILDING - FINAL
Permit Number - T18CM05106
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2018 | BUILDING - FINAL | Approved | All ADA corrections have been completed for interior! | |
08/29/2018 | BUILDING - FINAL | Correction Required | ADA Bathrooms. Toilet handle to be on open side at 2 toilets, Placard to be at 60" to center at strike side wall of doors, International symbol required at 4 locations as discussed-warehouse entry for retail, between mens and womens bathroom wall, at front door or glass next to it at 48", and at hallway leading to other bathroom. Urinal to be 17" from floor to top lip of urinal. Sinks to be a max of 34" to the rim. mirror to be 40" to the visible glass at bottom of the mirror. | |
08/28/2018 | BUILDING - FINAL | Not ready for Inspection | NR, will call in soon | |
08/27/2018 | BUILDING - FINAL | Not ready for Inspection | need fire extinguishers and cabinets installed. Need fire alarm inspection cleared by fire department. Missing soap dispensers, sanitary napkin, paper towel dispensers, cannot check ADA Heights if not installed. Need scald guards installed under all Ada accessible sinks. |