Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T18CM05016
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2019 | PLUMBING - FINAL | Approved | ||
11/06/2019 | PLUMBING - FINAL | Denied | 1- Missing rear hose bib. 2- Missing clean out adapter and plug. 3- Missing water hammer arrestor for the dishwasher water supply. 4- Dishwasher drain hose not secured to bottom of countertop. 5- Water heater missing drip pan. 6- Shall provide information for verification that the pressure reducing valve has a built in bypass. |