Permit: T18CM04977

Parcel: 205945920

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T18CM04977

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/10/2018 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/31/2018 EXT METAL CLIPS/EXT SHEATHING Cancelled
07/27/2018 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1. FINISH NAILING BIRD BLOCKING CLIPS
2. AO4M'S MECHANICAL TRUSSES ONLY HAVE ONE BEARING POINT NOT TWO. FOLLOW TRUSS CALCS AND LEAVE 1/2" FOR DEFLECTION.
3. A02'S ALSO ONLY HAVE ONE BEARING POINT, COUPLE OF THEM SITTING ON BEDROOM WALL. ALLOW 1/2" FOR DEFLECTION.
4. MISSING H2.5 CLIPS NE CORNER OF GARAGE.
5. MISSING TRIMMER STUD UNDER 4BY12 AT PATIO.
6. FIX GABLE BRACING, NEEDS TO BE AT 45 DEGREE ANGLE AND ADD STIFFNER IF OVER 6'