Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T18CM04874
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/05/2018 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/04/2018 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE THE MINIMUM TRAP ARM DISTANCE FOR THE CLOTHES WASHER TRAP ARM. 2- RE TEST THE SYSTEM * |
|
08/31/2018 | PLUMBING - INTERMEDIATE | Not ready for Inspection | Corrections still stand as they were not completed on this re-inspection. | |
08/30/2018 | PLUMBING - INTERMEDIATE | Correction Required | Screw closet rings to slab. Rat proof around all missed at sole plates and where offst closet ring was installed. Fill all ABS with water through roof. Strap all Black Iron gas pipe as required. |